12.04.2009

A310-200/300 COMM CVR

  
CVR
1.       ALL VOICE FROM AIU GOES TO CVR
2.       JACKS:
        ON CVR UNIT:
        FUEL PNL: HEARING VOICES ONLY NOT SPEAK
        CVR PNL: COME FROM CVR


3.       TO EARASE CVR PARK BRAKE SET AND RED BUTTON PUSH FOR 2SEC A/C MUST ON GND AND SYS ON 400HZ TONE HEARED IN HANDSET JACK
4.       CVR  AND DFDR POWERED IF DFDR SW ON OR ENG RUN
5.       CVR PNL HAS AN AMP AFTER MICE
6.       CVR LOCATION IS PRESSURIZED AREA
7.       CVR POWERED FROM 402XP(EMR AC BUS) AND 306PP(ESS DC BUS)
8.       CVR OFF 5MIN  AFTER ENG SHUT DOWN