- OIL OUT TEMP OF APU SENT TO ECB
- EMER GEN IS 3 PHASE 5KVA IS IN W/W DRIVEN BY BLUE HYD
- STATIC INV IS 1 PHASE
- TR’S HAS 200A OUTPUT
- STATIC INV HAS 1KVA OUTPUT
- 4XP (AC ESS BUS) NORMALLY POWERED BY AC BUS 1
- RAT EXT DONE BY BAT POWER
- TR #2 POWERED FROM EXT POWER WHEN MAINT BUS AND FROM AC BUS 2 WHEN EXT POWER ON
- 6PP (DC GND/FLT BUS) POWERED FROM TR 2 IN MAINT BUS AND FROM DC BUS 2 IN EXT POWER ON
- IF TR2 FAIL 6PP AUTO SUPPLY BY TR1
- YELLOW CB MEANS WE HAVE TO PULL THEM IN BAT ONLY
- 4PP (DC ESS BUS) NORMALLY POWERED BY 3PP (DC BAT BUS) AND ESS TR IF BOTH TR’S FAIL AND BATT2 IN EMER GEN OR ESS TR FAIL
- IF EMER GEN FAIL , GCU OFF THE EXCITE FIELD , GLC AND SOL VALVE
- IN ESS TR FAIL RAT & EMER GEN FAULT COMES ON
- RAT EXT SOL SUP BY HOT BUS1 BUT AFTER DELAY FROM PMG OF CSM/G
- CSM VALVE SOL SUP BY BAT2
- DC BAT BUS NORMALLY POWERED BY DC BUS 1(1PP)
- AC ESS SHED BUS (8XP) AND DC SHED BUS ARE DISCONNECTED IN EMER GEN FAIL
- ESS TR POWERS DC ESS BUS POWERED BY EMER GEN
- ESS TR POWERED BY AC ESS BUS & EMER GEN
- MAIN GALLEY SHED IN SINGLE ENG AND IF NOT AUTO SHED BTC LOCKOUT INHIBITED TO ALLOW GALLEY SW SELECT OFF
- GLC (GEN LINE CONT) IS IN COCKPIT
- THERE IS 6HOLE CT IN FWD CARGO AND 3 HOLE CT IN IDG TO ENSURE CONTINUITY
- IDG OIL COOLER BYPASS VLV OPEN IF OIL TEMP < 40°C AND
- 140°C : ADVISORY
- 185°C : MASTER CAUTION
- 200°C : THERMAL DISCON AND IDG MUST REPLACED
- EMER GEN IS CSMG (CONSTANT SPEED MOTOR GEN)
- GAPCU (GND & AUX POWER CONT UNIT) CONTROLS APU AND EXT GEN
- GPCU IN CLASSIC VER REPLACED BY GAPCU
- GAPCU HAS PTC (POSITIVE COEFFICIENT TEMP) LIGHT ON IN SHORT CIRCUIT DET
- GAPCU HAS IMR (INTERLOCK MONITOR RELAY) WHICH INTERLOCKS VOLTAGE BETWEEN 13 AND 42VDC
- GCR (GEN CONT RELAY & PRR (POWER READY RELAY) TRIPPED IF POR (POINT OF REGULATION) REACH:
- >130V OR <101
- 435HZ
- 50A
- LGCIU SENDS SIG TO GAPCU TO ENABLE COMMUNICATION BETWEEN GCU & GAPCU & CFDIU
- COMMERCIAL SW OFF THEN :
a. CABIN & CARGO LIT’S OFF
b. WATER & TOILET SYS INOP
c. DRAIN MAST HEAT INOP
d. GALLEY OFF
e. ENTERTAINMENT OFF
- IF APU OVER LOAD THEN BOTH GALLEY AUTO SHED
- IF IDG OVERLOAD IT MUST MANUALLY SHED
- 2 EGIU (ELECT GEN INTERFACE UNIT) CONVERT ANALOG TO ARINC FOR SDAC
- EACH EGIU HAS 2 CHANNEL:
a. CH1 FOR OWN SIDE GCU
b. CH2 FOR APU OR EXT PWR (EGIU1 CONN TO EXT PWR)
- DURING START BATT2 THEN PMG SUPP THE CSMG
- RAT AUTO EXT IF AC BUS1 & 2 LOST AND A/S>100KTS
- EMER GEN INOP<100KNT SO INV SUPP THE ESS BUS UNTIL 50 KNT
- BELOW 100 KNT DC ESS BUS SUP BY BAT2
- BELOW 50 KNT AC ESS OFF
- STATIC INV SUPP BY HOT BAT1
- IF EMER GEN FAIL ESS BUS’S ARE SUPP BY BAT 2 & STATIC INV
- IF EMER GEN FAIL BCL (BAT CHARGE LIMIT) SENDS SIG TO ILLUM THE FAULT LIGHT OF EMER GEN
- BCL FUNC :
- CONTROL BAT CONTACTORS
- RAT & EMER GEN FAULT CONT
- STATIC INV MONITORING
- INHIBITION OF APU START SEQUENCE
- TO TEST STAT INV PUSH EMER GEN TEST P/B WHICH SIMULATES 50 KNT (NO HYD NEEDED)
- AC ESS FEED FAULT LIT ON WHEN DOES NOT FEED SO IT MUST SW TO ALTERNATE(AC BUS2)
- IF GEN1 LINE SMOKE( AT EMER PWR PNL) ILLUM THEN MUST OFF THE LINE (GLC1 OPENED)
- WHEN GEN1 LINE P/B OUT , GCU RESET
- THERE ARE 2 BAT 26.5VDC,23AH,NI-CAD
- GEN ’S PRIORITY:
1. OWN SIDE GEN
2. EXT PWR
3. APU
4. OPPOSITE SIDE GEN
- GCU MONITORS IN & OUT OIL TEMP OF IDG BUT SHOWN ONLY OIL OUT TEMP ON ECAM
- IF OUT TEMP FAIL GCU ADDS A NOMINAL VALUE
- PMG IS ON IDG DIFF OUTPUT GEAR
- FILTER CLOG POP OUT IF ΔP>50 PSI
- STATIC INV RUN WHEN
- APU START TO SUPP FUEL PUMP
- GEN START ON BAT FOR IGN
- EMER CONFIG
- EMER GEN IS IN W/W AND ITS GCU IN L/H AV BAY
- IDG HAS HYD SERVO VALVE FOR CONTROL FRQ CONT BY GCU REFERENCE FRQ SIG
- INV FAULTS ARE SENT TO BCL TO MEMORIZE AND DISPLAY ON ECAM
- IDG DISCONNECTION INHIBITED WHEN ENG NOT RUN(FROM OIL LOW PRESS)
- TR'S ARE PROTECTED AGAINST OVER HEAT AND MINIMUM CURRENT
- TR2 MIN CURRENT DETECTION INHIBITED WHEN AC & DC GND/FLT BUS POWERED BY EXTERNAL POWER
- EMER GEN TEST P/B CAUSE INVERTER AND EMER GEN TEST AND BECOME INLINE
- RAT & EMER GEN P/B CAUSE ACTIVATION OF BOTH EVEN IN GND AND COLD CONDITION
- INVERTER INDICATION AVAIL ONLY IN ITS OPERATION
- STATIC INVERTER OPERATES IN :
- APU START TO SUP FUEL PUMP
- ENG START ON BAT
- RAT EXTENSION
- EMER CONFIG
- DC BAT BUS CAN SUP BY BOTH BAT
- WHEN ENG START RUN EXCITER FIELD REDUCED INSIDE OF GCU
- IDG FAULT INDICATED IF OVERHEAT & LOW OIL PRESS
- WHEN PARALLEL FEEDERS OPEN GCR AND GLC OPEN
- ZONE1 FAULT CAUSE GEN OFF BUT FAULT IN ZONE2 : ALSO AC BUS WILL OFF
- DIFF PROTECTION RESET BY ENG P/B (MAX 2 TIMES)
- PMR (PIN MONITOR RELAY) MONITORS EXT PWR RECEPTACLE VOLTAGE
- GPCU POWERED IN GND FROM GND CART AND DC BAT BUS
- IF ANY TR FAIL OTHER TR REPLACED FOR DC BUS BUT DC ESS TRANSFERRED TO ESS TR (FROM DC BAT BUS)
- TR'S CAN RESET FROM MCDU AND A P/B IN AV BAY
- BAT FAULT IF THERMAL RUNAWAY AND INTERNAL SHORT CIRCUIT
- IN EMER CONFIG WHEN APU STARTS BAT BUS CONN TO BAT'S
- APU START INHIBITED IF EMER CONFIG IF L/G EXT OR BEFORE CSM COUPLE (OR AFTER 45S)
- ON GND IF BAT BELOW 22V IT ISOLATED
- ON BAT REFUEL IS POSSIBLE FOR 10MIN IF REF ON BAT NOT SELECTED (NO PWR AVAIL)
- TO AVOID COMPLETE LOSS OF FUEL PUMPS SUPP IN SMOKE, GEN 1 LINE P/B IS RELEASED OUT TO OPEN GLC1. BUT GEN 1 IS STILL EXCITED AND SUPPLIES FUEL PUMPS 1LH AND 1RH.