12.05.2010

A320 CH26



1.       LOOPS MONITORED BY 3 FDU (FIRE DET UNIT) AND SENT TO FWC
2.       WHEN FIRE P/B RELEASE OUT :
a.       FUEL,HYD,ELEC,BLEED CUT
b.      EXTINGUISH SYS ARM
c.       SQUIB AND FIRE LIT’S ON
3.       DISCH LIT ON WHEN BOTTLES EMPETY
4.       APU HAS ONE BOTTLE IN FWD OF FIREWALL AND ENG ‘S HAS 2 IN PYLON ACCESS FROM BOTH SIDE
5.       APU EXTING SYS CAN TEST ON O/H PNL
6.       AEVC(AVIONIC EQUIP VENT CONT) MONITORS AV COOLING
7.       1 SMOKE DET INSTALLED ON EXT DUCT IN AV COMPARTMENT
8.       AV SMOKE IND:
1.       EMER ELEC PNL: SMOKE LIT ON GEN1 LINE P/B
2.       VENT PNL: FAULT LIT ON BLOWER AND EXT FAN P/B
9.       CARGO & LAV SMOKE DET :
a.       CLASSIC: SDCU (SMOKE DET CONT UNIT)
b.      ENHANCED: CIDS (CABIN INTERCOM DATA SYS) WHICH INCLUDED SDF (SMOKE DET FUNCTION)
10.   EACH CARGO HAS 2 SMOKE DET AND 1 BOTTLE FOR BOTH CARGO (2 IS OPTION)




 